UNIDRALL
100 |
Single
core cables for motors and drives feeding |
M•• |
UNIDRALL
100 C |
Single
core shielded cables for motors
and drives feeding |
M•• |
UNIDRALL
110 |
Single
core cables at low capacitance
for motors and drives
feeding |
M••• |
UNIDRALL
110 C |
Single
core shielded at low capacitance cables
for motors
and drives feeding |
M••• |
UNIDRALL
200 |
Single
core cables for motors and drives feeding |
M•••• |
UNIDRALL
200 C |
Single
core shielded cables for motors
and drives feeding |
M•••• |
UNIDRALL
2100* |
Multicore
cables, water resistant with UL and CSA approvals |
M• |
UNIDRALL
2100 C* |
Multicore
shielded cables, water resistant with UL and CSA
approvals |
M• |
UNIDRALL
2500* |
Multicore
shielded cables, for commanding, controlling and
signalling for chain installations |
M• |
UNIDRALL
2500 C* |
Multicore
cables, for commanding, controlling and signalling
for chain installations |
M• |
UNIDRALL
2500 UL* |
Multicore
cables, for commanding, controlling
and signalling
for chain installations |
M•• |
UNIDRALL
2500 C UL* |
Multicore
shielded cables, for commanding, controlling and
signalling for chain installations |
M•• |
UNIDRALL
2505* |
Multicore
cables, for commanding, controlling and signalling
for chain installations with
high chemical and mechanical resistances |
M••• |
UNIDRALL
2505 C* |
Multicore
shielded cables, for commanding, controlling and
signalling for chain installations
with high chemical and mechanical resistances |
M••• |
UNIDRALL
2510 |
Multicore
cables, for commanding, controlling and signalling
for chain installations with
high chemical and mechanical resistances |
M••• |
UNIDRALL
2510 C |
Multicore
shielded cables, for commanding, controlling and
signalling for chain installations
with high chemical and mechanical resistances |
M••• |
UNIDRALL
2520* |
Multicore
cables, for commanding, controlling and signalling
for chain installations with
high chemical and mechanical resistances |
M•••• |
UNIDRALL
2520 C* |
Multicore
shielded cables, for commanding, controlling and
signalling for chain installations
with high chemical and mechanical resistances |
M•••• |
UNIDRALL
2520 C-TP |
Multipair
shielded cables, for commanding, controlling and
signalling for chain installations
with high chemical and mechanical resistances |
M•••• |
UNIDRALL
2600 |
Multicore
cables, for commanding, controlling and signalling
for very long and vertical chain
installations |
M•••• |
UNIDRALL
2600 C |
Multicore
shielded cables, for commanding, controlling and
signalling for very long and vertical chain installations |
M•••• |
appendix |
|
|
|
|
NOTE:
Cables for dynamic
installation performances:
• 160 m/min 5 m/s2 min
1.000.000 cycles,
• • 200 m/min 15 m/s2 min
3.000.000 cycles,
• • • 250 m/min 30 m/s2 min
5.000.000 cycles,
• • • • 300 m/min 40 m/s2,
min 5.000.000 cycles.
F fixed installation
M dynamic installation
* Available in stock
|
|