UNIRAIL S – EN 50264-3-2 300 V – type MM Item n° Crosssection [mm²] Diameter [mm] Cable mass [kg/km] RB401 2x1 5,3 ÷ 6,2 42 RB425 3x1 5,7 ÷ 6,9 58 RB402 4x1 6,1 ÷ 7,2 67 RB426 5x1 6,9 ÷ 8,1 95 RB403 7x1 7,5 ÷ 8,7 111 RB428 8x1 8,5 ÷ 9,7 140 RB404 9x1 9,1 ÷ 10,6 150 RB427 10x1 9,8 ÷ 11,2 170 RB405 12x1 9,8 ÷ 11,5 180 RB433 16x1 11,6÷ 12,4 268 RB436 18x1 12,3÷ 13,1 303 RB406 19x1 11,7 ÷ 13,7 278 RB407 24x1 14,1 ÷ 16,5 363 RB408 32x1 15,5 ÷ 18,2 468 RB409 37x1 16,1 ÷ 18,9 530 RB410 40x1 16,7 ÷ 19,6 572 RB411 4x1,5 7,3 ÷ 8,6 94 RB434 5x1,5 9,0 ÷ 9,8 168 Item n° Crosssection [mm²] Diameter [mm] Cable mass [kg/km] RB412 7x1,5 8,7 ÷ 10,2 153 RB429 8x1,5 9,8 ÷ 11,0 190 RB413 9x1,5 10,9 ÷ 12,7 197 RB414 12x1,5 11,8 ÷ 13,8 257 RB415 19x1,5 14,2 ÷ 16,6 402 RB416 24x1,5 16,6 ÷ 19,5 503 RB417 32x1,5 18,7 ÷ 21,9 674 RB418 37x1,5 19,5 ÷ 22,8 761 RB437 3x2,5 7,6 ÷ 8,4 122 RB419 4x2,5 8,3 ÷ 9,8 138 RB420 7x2,5 10,2 ÷ 11,9 232 RB421 9x2,5 12,9 ÷ 15,1 309 RB422 12x2,5 13,9 ÷ 16,3 396 RB423 19x2,5 16,3 ÷ 19,1 601 RB424 24x2,5 19,6 ÷ 22,9 776 RB430 2x1,5 6,7 70 RB431 6x1,5 9,3 150 RB432 2x2,5 7,5 96 2 1 UNIKA (Italy) – EN 50264-3-2 300 V 3x1 MMG - code TECHNICAL DATA Temperature rating up to and including 90°C Very low temperatures resistance (-40°C) Resistance to ozone, oils, fuels, acids and alkali Bending radius: refer to EN 50343 table 16 Range of approval: According to table 1 (cross-section 1 ÷ 2,5 mm²) of EN 50264-3-2 for cables rated 300V (see IMQ test certificate) CONSTRUCTION Type: multicore unscreened cable Conductor: tinned copper conductor according to class 5 EN 60228 Tape (optional): coloured tape Insulation: crosslinked compound, type EI109 according to Standard EN 50264-1, colour black with numbers with or without yellow-green if not otherwise stated (upon request compound type EI110) Tape: non-hygroscopic tape on the assembly Sheath: crosslinked compound, type EM104 according to Standard EN 50264-1, colour black if not otherwise stated Marking: UNIKA (Italy) – EN 50264-3-2 300V (core number x cross-section) MM (MMG with yellow-green) – WW/YYYY - traceability code Fire safety: hazard level HL3 according to Standard EN 45545-2 for indoor cables (EL1A) and outdoor cables (EL1B) Add letter G after the item number for cables with yellow/green conductor The characteristics of the products, described in the data sheet, do not constitute any contractual binding. UNIKA spa reserves the right to change the specifications without any notice. Partial or total reproduction of this document is forbidden. TDS 00/2025 Unless otherwise specified, all values are nominal, other values can be provided on request. The images are made for the sole purpose of illustrating the product and are purely indicative. 27 UNIKA - ROLLING STOCK CABLES - UNIRAIL S – EN 50264-3-2 300 V – type MM

RkJQdWJsaXNoZXIy NDUyMzc=