RW106B (1x2x0,50 + 1x0,50) EN 50200 RW106E (1x2x0,75 + 1x0,75) EN 50200 DC conductor resistance ≤ 40,1 Ω/km ≤ 26,0 Ω/km Capacitance 46 pF/m 50 pF/m impedance 120 Ω (±10%) Voltage rating 300 V Min insulation resistance ≥ 1,0 GΩxkm 1,0 GΩxkm Nominal velocity of propagation 100MHz 66% 75% Before EN 50200 test After EN 50200 test Before EN 50200 test After EN 50200 test Nominal attenuation 1 MHz < 12,0 dB/100m 10 dB/100m 10 dB/100m 1,5 MHz < 15,0 dB/100m 2 MHz < 17,0 dB/100m 14 dB/100m 14 dB/100m 3 MHz < 20,0 dB/100m Nominal weight 102 kg/km 148 kg/km Nominal diameter 8,0 mm 10,0 mm Minimum bending radius 10 x outer ø Temperature range -40 °C +90°C Standard reference EN 50200, EIA RS485 The characteristics of the products, described in the data sheet, do not constitute any contractual binding. UNIKA spa reserves the right to change the specifications without any notice. Partial or total reproduction of this document is forbidden. TDS 00/2025 Fire safety: cables are classified in compliance with the highest requirements established by hazard level HL3 into Standard EN 45545-2 for indoor cables (EL1A) and outdoor cables (EL1B). 65 UNIKA - ROLLING STOCK CABLES - UNIRAIL D – RS485 and BUS cables